How To Choose Chlorine Dioxide Generator For Hospital Sewage Disinfection
Mar 23,2020
General hospitals generally need to add 30-40g / h to treat 1T water, and specialist hospitals charge 50g / h.
Usually customers choose the chemical method full automatic chlorine dioxide generator (all medical wastewater treatment occasions). The advantage is that it can run fully automatically, can realize delayed water stop, automatic alarm, low level alarm shutdown, under pressure alarm shutdown, and over temperature. Alarms for material shortage, shutdown, etc., and the amount of dosing can be controlled according to the flow of incoming water and residual chlorine in the effluent. Save time and effort.
Raw material selection: 1: 31% hydrochloric acid and 99% sodium chlorate. Two: chlorine dioxide AB active agent.
Customers choose manual chlorine dioxide generator with chemical method (small medical wastewater treatment and automation requirements are not high)
The advantages are: small size, light weight, no electricity, small footprint, simple operation
Raw material selection: 1: 31% hydrochloric acid and 99% sodium chlorate. Two: It is using chlorine dioxide AB active agent.
Customers choose electrolytic chlorine dioxide generator and sodium hypochlorite generator.
The advantage is that only one raw material is needed: industrial salt. The raw materials are convenient to take, the storage is also convenient, the automatic operation is simple and convenient.
Customers choose single potassium persulfate compound powder for disinfection
Raw material is potassium monopersulfate composite powder
The advantage is
Dosing materials: potassium monopersulfate disinfection powder, sodium hypochlorite solution, chlorine tablets, chlorine powder, etc.
Transportation safety: The powder is stable in nature, easy to transport, non-dangerous goods, no leakage and other dangers, eliminating hidden safety hazards.
Storage safety: stable in nature, no hidden dangers of leakage, no need for emergency protection equipment, avoiding the hidden dangers of traditional disinfectant storage process.
Safe to use: simple operation, low dosage, no danger to operator safety, non-reactive equipment, dissolving powder does not generate hazardous gas, simple operation of equipment, no hidden danger in operation, no need for special care.
Detection safety: portable portable active oxygen detector, which can quickly complete water sample detection, convenient and safe.
Environmental protection: potassium persulfate disinfection powder, disinfected with active oxygen, non-chlorine disinfectant, disinfection without residual substances, no "three-in-one", no secondary pollution, harmless to the environment, non-volatile, and not harmful Pollution of the environment will not cause corrosion to the equipment, delay the service life of the equipment, and harmless the staff.
Energy saving: less usage, no need for large electrical equipment, 1/3 of traditional disinfection equipment.