During operation, if there are fiber debris entangled on the rotating brush shaft, it should be cleaned up in time to avoid affecting the normal operation of the machine.
Depending on the amount of rubbish, the rubbish hanging on the discharge plate should be cleaned regularly.
During the normal operation of the machine, once a month, use a grease gun to inject calcium-based grease into the nozzles of all lubricated parts.
The lubricating oil in the reducer must be replaced regularly. Generally, the equipment needs to be replaced with new oil after half a month of normal use, and every three months after that. Usually, pay attention to the oil level of the reducer.
Quarterly maintenance is performed on each grille decontamination machine (mainly through the action test to observe whether there is any abnormality). Annual maintenance of each grille decontamination machine (including cleaning the water chamber and the dirt at the bottom of the grille. Five-year comprehensive inspection (except for the annual mechanical inspection items, the gearbox lubricating oil needs to be replaced).