Attention in design and installation of fine bubble membrane tube diffuser
Dec 06,2018
When the fine bubble membrane tube diffuser is designed, the distance between the intake pipes is 1000mm ~ 4000mm, and the distance between L is considered as the technological conditions of sewage concentration, water quality and gas supply. Tube aerator can be installed after empty pool or water intake. The number of sleeves installed on each intake pipe depends on the length of the pool and the intake volume.
Each intake branch of tubular aerator should be distributed from the main intake pipe on the Bank of the pool. It should bend from the wall of the pool to about 400-500 mm from the water level, and the intake branch should be DN100. The suspension distance of tubular aerator from the bottom of the pool is 150-500 mm, which can also be according to the design requirements.
The intake branch of diffuser can adopt hose or plastic hard pipe according to user's requirements. After the installation of the empty pool, water must be injected in time to avoid the biological sharpener falling into the pool, to prevent welding flames, and to avoid damaging the rubber film tube. Tube aerator should not be under heavy pressure, should not be stacked outdoors, should be away from fire and hard objects, to avoid damage.www.khnwatertreatment.com